QA/QC  › Flooring & Finishing  › Floor Tile Adhesion
Test-report · QC-FLR-TST-001
Floor Tile Adhesion Pull-Off Test Report
12 checkpoints across 3 sections. After adhesive has cured (minimum 48 hrs), during or after tile laying phase
12 Checkpoints
3 Sections
Minimum 5 tests per 100 m² of flooring
QC Engineer, Testing Lab Technician

Checklist Preview

S.No.CheckpointIS RequirementStatus
A. TEST METHODOLOGY
A1Test method and standard compliance
Acceptance: Pull-off testing performed with calibrated equipment, minimum 5 samples per 100 m²
Testing shall follow EN 1348 or equivalent pull-off method
OK
NC
NA
HOLD
A2Sample location selection (representative areas, no edge/corner bias)
Acceptance: Samples from at least 3 different areas per section, documented with photos
Random sample selection for objective assessment
OK
NC
NA
HOLD
A3Equipment calibration (load cell calibration certificate current)
Acceptance: Equipment calibrated within 12 months, calibration certificate on file
Accurate measurement of adhesion strength
OK
NC
NA
HOLD
A4Test timing (minimum 48 hrs after tile laying, maximum 28 days)
Acceptance: Testing conducted 48 hrs to 28 days after laying, time recorded
Adhesive must be fully cured for valid testing
OK
NC
NA
HOLD
B. TEST RESULTS & ANALYSIS
B1Pull-off load measurement (in MPa or kg/cm²)
Acceptance: Minimum bond strength ≥2.0 MPa (≥20 kg/cm²) per tile
Accurate recording of adhesion strength values
OK
NC
NA
HOLD
B2Failure mode analysis (adhesive, cohesive, substrate failure)
Acceptance: Failure in adhesive or at tile-adhesive interface acceptable; cohesive failure in substrate unacceptable
Identify where failure occurred for bond quality assessment
OK
NC
NA
HOLD
B3Average strength calculation and acceptance criteria
Acceptance: Average ≥2.0 MPa, no single value <1.5 MPa, minimum 4 out of 5 samples pass
Statistical analysis of bond strength data
OK
NC
NA
HOLD
B4Data interpretation and non-conformance evaluation
Acceptance: All samples meet minimum criteria or areas identified for rework documented
Assess compliance with strength requirements
OK
NC
NA
HOLD
C. OBSERVATIONS & DOCUMENTATION
C1Surface condition observation (moisture, contamination on tile back)
Acceptance: Condition noted, any anomalies recorded and photographed
Document factors affecting adhesion quality
OK
NC
NA
HOLD
C2Adhesive coverage verification (visual inspection of failed sample)
Acceptance: Coverage >90% on tile back required; voids or dry spots identified
Assess adequacy of adhesive application
OK
NC
NA
HOLD
C3Photographic documentation of test procedure and failed samples
Acceptance: At least 3 photos per test location showing sample location, setup, and failure
Visual record of testing and failure patterns
OK
NC
NA
HOLD
C4Environmental conditions during testing (temperature, humidity)
Acceptance: Temperature 15-35°C, humidity recorded, unusual conditions noted
Record conditions that may affect results
OK
NC
NA
HOLD
A. TEST METHODOLOGY
A1Test method and standard compliance
Testing shall follow EN 1348 or equivalent pull-off method (IS 1237)
Pull-off testing performed with calibrated equipment, minimum 5 samples per 100 m²
OKNCNAHOLD
A2Sample location selection (representative areas, no edge/corner bias)
Random sample selection for objective assessment (IS 1237)
Samples from at least 3 different areas per section, documented with photos
OKNCNAHOLD
A3Equipment calibration (load cell calibration certificate current)
Accurate measurement of adhesion strength (IS 1237)
Equipment calibrated within 12 months, calibration certificate on file
OKNCNAHOLD
A4Test timing (minimum 48 hrs after tile laying, maximum 28 days)
Adhesive must be fully cured for valid testing (IS 1237)
Testing conducted 48 hrs to 28 days after laying, time recorded
OKNCNAHOLD
B. TEST RESULTS & ANALYSIS
B1Pull-off load measurement (in MPa or kg/cm²)
Accurate recording of adhesion strength values (IS 1237)
Minimum bond strength ≥2.0 MPa (≥20 kg/cm²) per tile
OKNCNAHOLD
B2Failure mode analysis (adhesive, cohesive, substrate failure)
Identify where failure occurred for bond quality assessment (IS 1237)
Failure in adhesive or at tile-adhesive interface acceptable; cohesive failure in substrate unacceptable
OKNCNAHOLD
B3Average strength calculation and acceptance criteria
Statistical analysis of bond strength data (IS 1237)
Average ≥2.0 MPa, no single value <1.5 MPa, minimum 4 out of 5 samples pass
OKNCNAHOLD
B4Data interpretation and non-conformance evaluation
Assess compliance with strength requirements (IS 1237)
All samples meet minimum criteria or areas identified for rework documented
OKNCNAHOLD
C. OBSERVATIONS & DOCUMENTATION
C1Surface condition observation (moisture, contamination on tile back)
Document factors affecting adhesion quality (IS 1237)
Condition noted, any anomalies recorded and photographed
OKNCNAHOLD
C2Adhesive coverage verification (visual inspection of failed sample)
Assess adequacy of adhesive application (IS 1237)
Coverage >90% on tile back required; voids or dry spots identified
OKNCNAHOLD
C3Photographic documentation of test procedure and failed samples
Visual record of testing and failure patterns (IS 1237)
At least 3 photos per test location showing sample location, setup, and failure
OKNCNAHOLD
C4Environmental conditions during testing (temperature, humidity)
Record conditions that may affect results (IS 1237)
Temperature 15-35°C, humidity recorded, unusual conditions noted
OKNCNAHOLD
Inspection Sign-Off
APPROVED
APPROVED WITH CONDITIONS
REJECTED
Test Summary
Name / Sign / Date
Average Bond Strength (MPa)
Name / Sign / Date
Number of Samples Tested
Name / Sign / Date
Pass/Fail Verdict
Name / Sign / Date
Remarks
Name / Sign / Date
Tested By
Name / Sign / Date
Reviewed By
Name / Sign / Date