IS 1443 : 2019Precast Terrazzo Tiles - Specification

PDFGoogleCompareBIS Portal
Link points to Internet Archive / others. Not hosted by InfraLens. Details
International Comparison — Coming Soon
CurrentFrequently UsedSpecificationBIMArchitectural · Flooring and Paving
PDFGoogleCompareBIS Portal
Link points to Internet Archive / others. Not hosted by InfraLens. Details
OverviewValues6InternationalTablesFAQ4Related

IS 1443:2019 is the Indian Standard (BIS) for precast terrazzo tiles - specification. This standard covers the material requirements, manufacturing process, physical properties, and testing methods for precast terrazzo tiles used in flooring and paving. It specifies dimensional tolerances, water absorption limits, transverse strength, and abrasion resistance to ensure long-term durability and aesthetic consistency in heavy-traffic applications.

Specifies requirements for precast terrazzo tiles for flooring, covering materials, dimensions, and performance characteristics.

Overview

Status
Current
Usage level
Frequently Used
Domain
Architectural — Flooring and Paving
Type
Specification
Earlier editions
IS 1443:1992
Typically used with
IS 269IS 383IS 1237IS 8042IS 4082
Also on InfraLens for IS 1443
6Key values3Tables4FAQs

BIM-relevant code. See the BIM Hub for ISO 19650, IFC, and LOD/LOIN frameworks used alongside it.

Practical Notes
! The wearing layer must be properly compacted during manufacturing to minimize voids, reduce water absorption, and prevent pitting.
! Proper curing is critical to prevent warping and ensure the wearing layer achieves the necessary hardness for grinding and polishing.
! Ensure the sub-floor is perfectly leveled before laying; hollow spots beneath the tiles can lead to cracking under point loads.
Frequently referenced clauses
Cl. 4MaterialsCl. 5ManufactureCl. 6Dimensions and TolerancesCl. 7Physical RequirementsCl. 9Sampling and Criteria for Conformity
Pulled from IS 1443:2019. Browse the full clause & table index below in Tables & Referenced Sections.
terrazzoconcretemarble chipscementpigments

International Equivalents

🌐
International Comparison — Coming Soon
We're adding equivalent international standards for this code.

Key Values6

Quick Reference Values
Water absorption (Max)10%
Tolerance on length and breadth± 1 mm
Tolerance on thickness± 3 mm
Tolerance on flatness1 mm
Minimum wearing layer thickness (small chips)5 mm
Minimum wearing layer thickness (large chips)6 mm
Key Formulas
Water Absorption (%) = [(M2 - M1) / M1] * 100
Wet Transverse Strength (N/mm²) = (3 * P * L) / (2 * b * d²)

Tables & Referenced Sections

Key Tables
Table 1 - Minimum Thickness of Wearing Layer
Table 2 - Tolerances on Dimensions
Table 3 - Physical Requirements (Abrasion, Water Absorption, Modulus of Rupture)
Key Clauses
Clause 4 - Materials
Clause 5 - Manufacture
Clause 6 - Dimensions and Tolerances
Clause 7 - Physical Requirements
Clause 9 - Sampling and Criteria for Conformity

Related Resources on InfraLens

Cross-Referenced Codes
IS 269:2015Ordinary Portland Cement - Specification
→
IS 383:2016Coarse and Fine Aggregates for Concrete - Spe...
→
IS 1237:2015Cement Concrete Flooring Tiles - Specificatio...
→
IS 8042:1989White Portland cement – Specification
→
IS 4082:1996Recommendations on stacking and storage of co...
→

Frequently Asked Questions4

What is the maximum permissible water absorption for precast terrazzo tiles?+
The maximum permissible water absorption is 10 percent by mass.
What is the minimum thickness required for the terrazzo wearing layer?+
It must be at least 5 mm or 6 mm, depending on the maximum size of the marble chips used in the mix.
What are the allowed dimensional tolerances for length and width?+
The allowed tolerance for both length and width is ± 1 mm.
Can ordinary portland cement be used for the wearing layer?+
Yes, but white portland cement (IS 8042) or a mixture with suitable pigments is commonly used to achieve the desired aesthetic finish.