HandbookPile Bearing Capacity (IS 2911)

Pile Bearing Capacity (IS 2911)

IS 2911 (Parts 1, 2, 3, 4) · Cl 6 — Determination of pile capacity (static formula & load test)
Methods to estimate single pile capacity per IS 2911. Static formula uses soil parameters (cohesion c, friction angle φ, SPT N) to compute end-bearing and skin-friction. The result is checked by full-scale load test on test piles. Use the lower of formula and load test capacity, with appropriate factor of safety.
IS 2911
40 items shown
Pile Capacity — Static Formula (IS 2911 Pt 1/2)
Ultimate capacity Qu = Qb + Qs (end bearing + skin friction)
ParameterFormula / ValueResultNote
Total ultimate capacity QuQu = Qb + QskNEnd bearing + skin friction
End bearing QbAb × (cb × Nc + γ' × D × Nq)kNCohesion + overburden contributions
Skin friction Qs (cohesive)α × c̄ × AskNα = adhesion factor (0.3–1.0); c̄ = avg cohesion
Skin friction Qs (granular)K × σv' × tan δ × AskNK = lateral earth pressure coeff; δ = pile-soil friction
Allowable capacity QaQu / FoSkNFoS = 2.5 (formula) / 2.0 (load test)
FoS — IS 2911 Cl 6.5Static formula: 2.5Initial load test: 2.0Routine load test: 1.5
Bearing Capacity Factors (Terzaghi/Meyerhof)
ParameterFormula / ValueResultNote
Nc — cohesion factor9 (deep piles, c-soil)Skempton; valid for L/D ≥ 4
Nq — overburden factorFunction of φTabulatedSee sub-table below
Nq @ φ = 0°1Pure cohesive
Nq @ φ = 25°13Loose granular
Nq @ φ = 30°20Medium dense sand
Nq @ φ = 35°31Dense sand
Nq @ φ = 40°50Very dense
Nq @ φ = 45°82Extremely dense / dense gravel
SPT N to Pile Capacity (Quick Estimation)
Meyerhof method for cohesionless soil
ParameterFormula / ValueResultNote
End bearing (driven, sand)qb = 40 × N × (Lb/D)≤ 400 N kN/m²L_b = embedment in bearing layer
End bearing (bored, sand)qb = 13 × N × (Lb/D)≤ 130 N kN/m²Bored = lower than driven
Skin friction (driven, sand)fs = 2 × N̄ kN/m²N̄ = avg N along shaft
Skin friction (bored, sand)fs = N̄ kN/m²Lower than driven
Skin friction (clay, undrained)fs = α × cuα = 1.0 (cu < 25); 0.5 (>50)Linear interp between
Quick rule (medium dense sand)Qa ≈ 7–10 × N (kN per pile)For 500 mm dia bored pile
Typical Pile Capacities (Quick Reference)
ParameterFormula / ValueResultNote
300 mm dia, boredLength 8–12 m200–350 kNLight-duty foundations
400 mm dia, boredLength 10–15 m350–600 kNResidential, low-rise
450 mm dia, boredLength 12–18 m500–800 kNMid-rise residential
500 mm dia, boredLength 15–20 m650–1000 kNG+10 residential
600 mm dia, boredLength 15–25 m900–1500 kNMid-rise commercial
750 mm dia, boredLength 20–30 m1500–2500 kNHigh-rise, heavy industrial
1000 mm dia, boredLength 25–40 m2500–4500 kNBridges, major buildings
1200 mm dia, boredLength 30–50 m3500–6500 kNBridge piers, transfer columns
Pile Load Test (IS 2911 Pt 4)
Field verification of computed capacity
ParameterFormula / ValueResultNote
Initial load test (test pile)Apply 2.5 × design loadIncrements of 20%Determines ultimate; 2 piles min per project
Routine load testApply 1.5 × design loadOn working piles0.5% of total piles, min 2
Maintained load testEach load held until settlement rate < 0.1 mm/30minSlower, more reliable
Cyclic load testLoad-unload cyclesSeparates skin friction & end bearing
Acceptance — settlement at 1.5 × design≤ 12 mm OR 2% of pile diaWhichever less
Acceptance — settlement at 2.5 × design≤ 25 mmInitial load test
Acceptance — net residual settlement≤ 6 mm OR 80% of totalRecovery test
Pile Group Effects
ParameterFormula / ValueResultNote
Group capacity (sand)ΣQ_individual × ηη = 1.0–0.7Efficiency depends on spacing
Min spacing (driven)≥ 3 × pile diaCl 8.4
Min spacing (bored)≥ 2.5 × pile dia
Max spacing≤ 4 × pile diaBeyond this, pile cap heavy
Group settlement (clay)≈ 5–10 × single pile settlementLong-term consolidation
Notes
ALWAYS conduct soil investigation before pile design — formula needs c, φ, N, γ for each layer
Initial load test (2.5 × design load) is mandatory for projects with > 100 piles
Routine test on 0.5% of working piles (min 2) verifies workmanship
Bored cast-in-situ piles are most common in Indian urban work (low noise, limited space)
Driven piles give higher capacity per cross-section but cause vibration — restricted in cities
Pile cap depth = max(pile dia + 100 mm, 0.6 m typical)
Negative skin friction can reduce capacity if pile passes through compressible / fill soil — investigate
For end-bearing piles in rock, socket length ≥ 1 × pile dia; capacity often governed by rock strength
Get IS 2911 Pt 1 (driven), Pt 2 (under-reamed), Pt 3 (timber/precast), Pt 4 (load test) — different rules for each pile type
← Previous
Defects in Concrete — Causes & Remedies
Next →
BIM Concepts & Terminology
Generated by InfraLens · infralens.in