IS 17564 : 2021Precast Concrete Compound Wall Panels - Specification

PDFGoogleCompareBIS Portal
Link points to Internet Archive / others. Not hosted by InfraLens. Details
BS EN 12839 · ACI 551.2R · BS EN 14992
CurrentSpecializedSpecificationBIMMaterials Science · Precast and Prefabricated Concrete
PDFGoogleCompareBIS Portal
Link points to Internet Archive / others. Not hosted by InfraLens. Details
OverviewValues6InternationalTablesFAQ4Related

IS 17564:2021 is the Indian Standard (BIS) for precast concrete compound wall panels - specification. This standard specifies the requirements for materials, dimensions, physical properties, and testing of precast concrete panels used for compound or boundary walls. It covers aspects like dimensional tolerances, transverse strength, water absorption, and marking for quality assurance.

Covers the requirements for precast concrete panels specifically designed for compound wall construction.

Overview

Status
Current
Usage level
Specialized
Domain
Materials Science — Precast and Prefabricated Concrete
Type
Specification
International equivalents
BS EN 12839:2012 · British Standards Institution (BSI) / European Committee for Standardization (CEN), UK / EuropeACI 551.2R-10 · American Concrete Institute (ACI), USABS EN 14992:2007+A1:2012 · British Standards Institution (BSI) / European Committee for Standardization (CEN), UK / EuropeAS 3850.1:2015 · Standards Australia, Australia
Typically used with
IS 269IS 383IS 456IS 516IS 1786IS 2386IS 9103
Also on InfraLens for IS 17564
6Key values3Tables4FAQs

BIM-relevant code. See the BIM Hub for ISO 19650, IFC, and LOD/LOIN frameworks used alongside it.

Practical Notes
! Ensure proper handling and erection procedures are followed to avoid cracking the panels, as they are primarily designed for transverse loads (like wind) and not for heavy loads during handling.
! Verify the manufacturer's test certificates for compliance with this standard before accepting material delivery.
! The stability of the wall system depends critically on the correct installation of supporting columns and foundations, which are outside the scope of this panel-specific standard.
Frequently referenced clauses
Cl. 4MaterialsCl. 5Dimensions and TolerancesCl. 6Physical RequirementsCl. 7Workmanship and FinishCl. 8Sampling and Criteria for ConformityCl. 9Marking
Pulled from IS 17564:2021. Browse the full clause & table index below in Tables & Referenced Sections.
precast concretecementsteelaggregatesadmixtures

International Equivalents

Similar International Standards
BS EN 12839:2012British Standards Institution (BSI) / European Committee for Standardization (CEN), UK / Europe
HighCurrent
Precast concrete products - Elements for fences
Directly addresses precast concrete elements (panels, posts) for constructing fences and boundary walls.
ACI 551.2R-10American Concrete Institute (ACI), USA
MediumCurrent
Design and Construction of Precast Concrete T-Beams for Boundary Walls
A design guide specifically for precast boundary walls, but is not a mandatory product specification.
BS EN 14992:2007+A1:2012British Standards Institution (BSI) / European Committee for Standardization (CEN), UK / Europe
MediumCurrent
Precast concrete products — Wall elements
Covers general precast wall elements for buildings, including non-load bearing panels with similar manufacturing principles.
AS 3850.1:2015Standards Australia, Australia
LowCurrent
Prefabricated concrete elements, Part 1: General requirements
Provides general requirements for all precast concrete, not specific to fence panels, but covers materials and tolerances.
Key Differences
≠IS 17564 mandates a minimum concrete grade of M25, whereas European standards like BS EN 12839 focus on performance-based declared strength classes (e.g., C25/30) without a mandatory minimum.
≠Design wind loads in IS 17564 are determined using IS 875 (Part 3), which has wind zone maps and coefficients specific to India. International standards refer to their respective national/regional codes (e.g., Eurocode 1), leading to different design pressures.
≠IS 17564 specifies a prescriptive reinforcement cover (e.g., 20 mm for 'Moderate' exposure), while Eurocodes (referenced by EN standards) use a more detailed system based on specific exposure classes (XC, XD, XS etc.) and intended service life, which can result in different cover values.
≠IS 17564 provides a fixed sampling frequency for compressive strength testing (e.g., 3 cubes per 50 panels). In contrast, EN standards heavily rely on a Factory Production Control (FPC) system, allowing for reduced testing frequency if consistent quality is statistically demonstrated.
Key Similarities
≈Both IS 17564 and its international counterparts require constituent materials (cement, aggregates, steel, admixtures) to conform to their respective national parent standards.
≈All standards emphasize the importance of dimensional accuracy by specifying permissible tolerances for length, height, thickness, and squareness to ensure interoperability and aesthetics.
≈The fundamental test to verify flexural capacity, the transverse load test, is a common requirement to ensure panels can resist out-of-plane loads like wind.
≈Durability is a core consideration across all standards, addressed through specifications for minimum cement content, maximum water-cement ratio, and adequate reinforcement cover, tailored to environmental conditions.
Parameter Comparison
ParameterIS ValueInternationalSource
Minimum Concrete GradeM25 (25 N/mm² characteristic cube strength)No absolute minimum; manufacturer declares a class (e.g., C25/30 is common)BS EN 12839:2012
Reinforcement Cover (Moderate Exposure)20 mm≥25 mm (For exposure class XC3/XC4, 50-year life, common equivalent to moderate)BS EN 1992-1-1 (via EN 12839)
Water Absorption LimitMaximum 6% by massMaximum 6% by mass (Corresponds to the highest durability class for water absorption)BS EN 12839:2012
Dimensional Tolerance (Length/Height >1.5m)± 5 mm± 5 mm (for Class 1), ± 8 mm (for Class 2)BS EN 12839:2012
Dimensional Tolerance (Thickness)± 3 mm± 3 mm (for Class 1), ± 5 mm (for Class 2)BS EN 12839:2012
Minimum Cement Content (Moderate Exposure)300 kg/m³300 kg/m³ (for exposure class XC4, a similar environment)BS EN 206 (via EN 12839)
Maximum Water-Cement Ratio (Moderate Exposure)0.500.55 (for exposure class XC3, a similar environment)BS EN 206 (via EN 12839)
⚠ Verify details from original standards before use

Key Values6

Quick Reference Values
Minimum grade of concreteM25
Minimum nominal cover to reinforcement15 mm
Maximum water absorption by mass10 %
Minimum transverse strength at 28 days4.0 kN
Dimensional tolerance for length/width± 5 mm
Dimensional tolerance for thickness± 3 mm

Tables & Referenced Sections

Key Tables
Table 1 - Dimensional Tolerances for Panels
Table 2 - Physical Requirements for Panels
Table 3 - Scale of Sampling for Precast Concrete Panels
Key Clauses
Clause 4 - Materials
Clause 5 - Dimensions and Tolerances
Clause 6 - Physical Requirements
Clause 7 - Workmanship and Finish
Clause 8 - Sampling and Criteria for Conformity
Clause 9 - Marking

Related Resources on InfraLens

Cross-Referenced Codes
IS 269:2015Ordinary Portland Cement - Specification
→
IS 383:2016Coarse and Fine Aggregates for Concrete - Spe...
→
IS 456:2000Plain and Reinforced Concrete - Code of Pract...
→
IS 516:2021Methods of Tests for Strength of Concrete - P...
→
IS 1786:2008High Strength Deformed Steel Bars and Wires f...
→
IS 2386:1963Methods of Test for Aggregates for Concrete -...
→
IS 9103:1999Admixtures for Concrete - Specification
→

Frequently Asked Questions4

What is the minimum grade of concrete for precast wall panels?+
M25, as specified in Clause 6.1.
What is the maximum allowed water absorption?+
10 percent by mass, as per Table 2.
What is the dimensional tolerance for the length and thickness of a panel?+
The tolerance is ±5 mm for length/width and ±3 mm for thickness, according to Table 1.
What is the minimum required concrete cover for the reinforcement?+
The nominal cover to all reinforcement shall not be less than 15 mm (Clause 5.3).

QA/QC Inspection Templates

📋
QA/QC templates coming soon for this code.
Browse all 300 templates →