QA/QC  › Timber & Wood  › Timber Material Register
Register · QC-TMB-REG-001
Timber Material Register
23 checkpoints across 6 sections. Daily entries during entire timber material phase; from receipt through usage
23 Checkpoints
6 Sections
Daily entries; weekly and monthly reviews
Store Keeper, QC Engineer

Checklist Preview

S.No.CheckpointIS RequirementStatus
A. TIMBER RECEIPT & INSPECTION
A1Date & Delivery Challan No.
Acceptance: Dated entry with challan reference and delivery truck details
Record all timber deliveries
OK
NC
NA
HOLD
A2Timber Type & Grade (Species, Grade per IS)
Acceptance: Species name, grade (FG/SG/etc), recorded clearly
Material identification
OK
NC
NA
HOLD
A3Quantity (Pieces, Cubic Meters, Weight)
Acceptance: Count and volume recorded; cross-checked against challan
Material quantity tracking
OK
NC
NA
HOLD
A4Mill Certificate / Treatment Certificate
Acceptance: Receipt of certificates; MC data, treatment details noted
Verify sourcing and treatment
OK
NC
NA
HOLD
A5Receiving Inspection Status (Accepted/Rejected/Hold)
Acceptance: Status recorded with reason if rejected/on-hold
Quality decision at receipt
OK
NC
NA
HOLD
B. TESTING & VERIFICATION
B1Moisture Content Test Done (Y/N), Average MC %
Acceptance: MC test performed; result within 15% for structural, 12% for joinery
Verify seasoning requirement
OK
NC
NA
HOLD
B2Treatment Verification (if treated), Chemical & Retention
Acceptance: Treatment certificate reviewed; retention ≥4 kg/m³ verified
Confirm treatment adequacy
OK
NC
NA
HOLD
B3Visual Quality Check (Defects, Insect Damage, Staining)
Acceptance: Observations on knots, cracks, fungal stains; grade confirmed
Grade compliance verification
OK
NC
NA
HOLD
B4Test Reports Filed (Y/N), Report Reference Nos
Acceptance: All test reports filed and cross-referenced in register
Documentation completeness
OK
NC
NA
HOLD
C. STORAGE & MATERIAL CONTROL
C1Storage Location & Stack Identification
Acceptance: Storage area/stack number recorded; material identifiable on site
Material traceability
OK
NC
NA
HOLD
C2Storage Condition Assessment (Dry/Covered/Ventilated)
Acceptance: Checked regularly; covered, ventilated, off-ground storage confirmed
Proper storage maintenance
OK
NC
NA
HOLD
C3Inventory Status (In Stock, Issued for Use)
Acceptance: Current stock quantity recorded; issued materials tracked
Track material movement
OK
NC
NA
HOLD
C4Quantity Issued (Cubic Meters, Date, Purpose/Use)
Acceptance: Each issuance dated and documented with end use (frames/doors/etc)
Material consumption recording
OK
NC
NA
HOLD
Showing 13 of 23 checkpoints ·
A. TIMBER RECEIPT & INSPECTION
A1Date & Delivery Challan No.
Record all timber deliveries (IS 1141)
Dated entry with challan reference and delivery truck details
OKNCNAHOLD
A2Timber Type & Grade (Species, Grade per IS)
Material identification (IS 1141)
Species name, grade (FG/SG/etc), recorded clearly
OKNCNAHOLD
A3Quantity (Pieces, Cubic Meters, Weight)
Material quantity tracking (IS 1141)
Count and volume recorded; cross-checked against challan
OKNCNAHOLD
A4Mill Certificate / Treatment Certificate
Verify sourcing and treatment (IS 401)
Receipt of certificates; MC data, treatment details noted
OKNCNAHOLD
A5Receiving Inspection Status (Accepted/Rejected/Hold)
Quality decision at receipt (IS 1141)
Status recorded with reason if rejected/on-hold
OKNCNAHOLD
B. TESTING & VERIFICATION
B1Moisture Content Test Done (Y/N), Average MC %
Verify seasoning requirement (IS 1141)
MC test performed; result within 15% for structural, 12% for joinery
OKNCNAHOLD
B2Treatment Verification (if treated), Chemical & Retention
Confirm treatment adequacy (IS 401)
Treatment certificate reviewed; retention ≥4 kg/m³ verified
OKNCNAHOLD
B3Visual Quality Check (Defects, Insect Damage, Staining)
Grade compliance verification (IS 1141)
Observations on knots, cracks, fungal stains; grade confirmed
OKNCNAHOLD
B4Test Reports Filed (Y/N), Report Reference Nos
Documentation completeness (IS 1141)
All test reports filed and cross-referenced in register
OKNCNAHOLD
C. STORAGE & MATERIAL CONTROL
C1Storage Location & Stack Identification
Material traceability (IS 1141)
Storage area/stack number recorded; material identifiable on site
OKNCNAHOLD
C2Storage Condition Assessment (Dry/Covered/Ventilated)
Proper storage maintenance (IS 401)
Checked regularly; covered, ventilated, off-ground storage confirmed
OKNCNAHOLD
C3Inventory Status (In Stock, Issued for Use)
Track material movement (IS 1141)
Current stock quantity recorded; issued materials tracked
OKNCNAHOLD
C4Quantity Issued (Cubic Meters, Date, Purpose/Use)
Material consumption recording (IS 1141)
Each issuance dated and documented with end use (frames/doors/etc)
OKNCNAHOLD
Showing 13 of 23 ·
Inspection Sign-Off
APPROVED
APPROVED WITH CONDITIONS
PENDING REVIEW
Monthly Summary
Name / Sign / Date
Total Quantity Received (m³)
Name / Sign / Date
Total Quantity Used (m³)
Name / Sign / Date
Total Wastage/Loss (m³)
Name / Sign / Date
Loss Percentage (%)
Name / Sign / Date
Outstanding Issues
Name / Sign / Date
Store Keeper Name
Name / Sign / Date
QC Engineer Name
Name / Sign / Date