| S.No. | Checkpoint | IS Requirement | Status |
|---|---|---|---|
| A. STRUCTURAL INTEGRITY CHECKS | |||
| A1 | Uprights plumb and vertical; no visible bending or deformation Acceptance: Plumb verified; No bending; Deviation <1:250 | Cl. 5 — Vertical alignment | OK NC NA HOLD |
| A2 | Couplers all tight and secured; no missing bolts or nuts Acceptance: Sample check of couplers; All bolts present & tight | Cl. 6 — Connection integrity | OK NC NA HOLD |
| A3 | Bracing intact and secure; no damage or deformation Acceptance: Braces at 45°; No bending; Connections tight | Cl. 7 — Diagonal bracing | OK NC NA HOLD |
| A4 | Platform boards intact; no cracks, splitting, or rot visible Acceptance: Boards ≥50mm; No defects; Fully supported; No overhang >300mm | Cl. 8 — Platform condition | OK NC NA HOLD |
| A5 | Guard rails and toe board intact; proper height and continuity Acceptance: Rails 1.0-1.2m; Toe board ≥150mm; No gaps >120mm | Cl. 9 — Fall protection | OK NC NA HOLD |
| B. SAFETY EQUIPMENT & ACCESS | |||
| B1 | Access stairs/ladders stable and secure; no missing rungs Acceptance: Stairs level; Handrails secure; Rungs 300mm spacing | Cl. 10 — Access adequacy | OK NC NA HOLD |
| B2 | Warning signs and capacity labels visible and readable Acceptance: Signs posted at entry & critical points; Capacity clearly marked | Cl. 11 — Worker communication | OK NC NA HOLD |
| B3 | No obstacles or stored materials on working platform Acceptance: Platform clear; No tripping hazards; Debris removed | Cl. 12 — Platform cleanliness | OK NC NA HOLD |
| B4 | Catch platform below all work areas to collect dropped objects Acceptance: Catch tray/net installed; No gaps; Secured | Cl. 13 — Object drop protection | OK NC NA HOLD |
| C. WEATHER & ENVIRONMENTAL FACTORS | |||
| C1 | Scaffold stable in current wind conditions; no excessive swaying Acceptance: Wind speed <20 km/h for work; Guying if needed; Visual confirmation | Cl. 14 — Wind safety | OK NC NA HOLD |
| C2 | No water pooling on platform; drainage clear after rain Acceptance: Platform dry; Drainage holes clear; Slip risk minimal | Cl. 15 — Drainage | OK NC NA HOLD |
| C3 | No ice/frost on platform; accessible and non-slippery Acceptance: Platform surface dry/treated; Anti-slip if wet | Cl. 16 — Weather adaptation | OK NC NA HOLD |