| S.No. | Checkpoint | IS Requirement | Status |
|---|---|---|---|
| 1. SCOPE & OBJECTIVES | |||
| 1.1 | Scope: Define areas to be painted; total area in m²; building/floors/zones identified Acceptance: Clear identification; total area quantified; special areas noted (high traffic, wet areas) | Cl. 301 — Scope definition | |
| 1.2 | Objectives: State painting standard, finish quality, durability target, maintenance schedule Acceptance: IS 2395 compliance; 3-5 year touch-up typical; zero defects target | Cl. 301 — Goal setting | |
| 2. MATERIALS & SPECIFICATION | |||
| 2.1 | Paint specification: Type (emulsion/enamel), brand, grade, color; approval and shelf-life Acceptance: Approved product; test certs available; storage temp/shelf-life confirmed | Cl. 301 — Material specification | |
| 2.2 | Primer: Type, consumption rate, drying time; compatibility with paint confirmed Acceptance: Alkali-resistant primer for concrete/plaster; adhesion promoter for smooth surfaces | Cl. 301 — Primer specification | |
| 2.3 | Coverage rates: Primer, undercoat, finish per label; total quantity calculated Acceptance: Primer 8-12 m²/L; finish 10-15 m²/L; wastage factor 5-10% included | Cl. 301 — Material planning | |
| 3. EQUIPMENT & TOOLS | |||
| 3.1 | Application tools: Brushes (natural/synthetic), rollers (nap type), spraying equipment if applicable Acceptance: Quality tools; bristles intact; roller nap 6-10mm; spray gun if large areas | Cl. 301 — Equipment specification | |
| 3.2 | Measuring equipment: DFT gauge calibrated; thermometer; hygrometer; measuring tape Acceptance: Calibrated ±accuracy; documented; available on site | Cl. 301 — QC equipment | |