This standard (Part 4 of the IS 10124 series) provides the specifications for fabricated unplasticized PVC (PVC-U) caps intended for use in potable water supply systems. It details the material requirements by reference, dimensional standards for caps made from either pipe or sheet, essential performance tests, and marking criteria.

Fabricated PVC- U Fittings for Potable Water Supplies - Specification, Part 4: Specific Requirements for Caps

Quick Reference Values
Minimum Vicat Softening Temperature76 °C
Maximum Longitudinal Reversion5 %
Density Range1.40 to 1.46 g/cm³
Maximum Light Transmission (Opacity Test)0.2 %
Standard Pipe Lengths3 m and 6 m
Pressure Classes4, 6, 8, and 10 kgf/cm²
Key Formulas
σ = P(D-t) / 2t — Hoop stress calculation for hydrostatic pressure testing
Practical Notes
These pipes are specifically designated as 'Agri' pipes and should not be confused with or substituted for potable water pipes under IS 4985.
The standard covers both plain-ended suction pipes and delivery pipes which may have an integral socket.