IS 10124

: 2000

Fabricated PVC-U Fittings for Potable Water Supplies - Specification, Part 10: Specific Requirements for 45o Bends

CurrentFrequently UsedSpecificationBIMWater Resources · Plastic Piping System
Download PDFBIS PortalGoogle

This standard (Part 10) provides specific requirements for fabricated 45-degree bends made from unplasticized PVC (PVC-U) for use in potable water supply pipelines. It covers dimensions, tolerances, and marking, while referencing IS 10124 (Part 1) for general material properties, physical characteristics, and performance test methods.

Fabricated PVC-U Fittings for Potable Water Supplies - Specification, Part 10: Specific Requirements for 45o Bends

Quick Reference Values
Minimum Vicat Softening Temperature76 °C
Maximum Longitudinal Reversion5 %
Density Range1.40 to 1.46 g/cm³
Maximum Light Transmission (Opacity Test)0.2 %
Standard Pipe Lengths3 m and 6 m
Pressure Classes4, 6, 8, and 10 kgf/cm²
Key Formulas
σ = P(D-t) / 2t — Hoop stress calculation for hydrostatic pressure testing
Practical Notes
These pipes are specifically designated as 'Agri' pipes and should not be confused with or substituted for potable water pipes under IS 4985.
The standard covers both plain-ended suction pipes and delivery pipes which may have an integral socket.
Ensure proper storage away from direct sunlight to prevent UV degradation and brittleness.