IS 10124 : 2000Unplasticized PVC Pipes for Use in Suction and Delivery Lines of Agricultural Pump Sets

PDFGoogleCompareBIS Portal
Link points to Internet Archive / others. Not hosted by InfraLens. Details
EN ISO 1452-3 · AWWA C907 · AS/NZS 1477
CurrentFrequently UsedSpecificationBIMMaterials Science · Plastic Piping System
PDFGoogleCompareBIS Portal
Link points to Internet Archive / others. Not hosted by InfraLens. Details
OverviewValues6InternationalTablesFAQ4Related

IS 10124:2000 is the Indian Standard (BIS) for unplasticized pvc pipes for use in suction and delivery lines of agricultural pump sets. This standard specifies the requirements for unplasticized PVC (uPVC) pipes intended for use in suction and delivery lines of agricultural pump sets. It covers material composition, dimensions, physical and mechanical properties, performance tests, and marking for various pressure classes.

Unplasticized PVC Pipes for Use in Suction and Delivery Lines of Agricultural Pump Sets

Overview

Status
Current
Usage level
Frequently Used
Domain
Materials Science — Plastic Piping System
Type
Specification
International equivalents
EN ISO 1452-3:2022 · CEN / ISO (European Committee for Standardization / International Organization for Standardization), Europe/InternationalAWWA C907-20 · AWWA (American Water Works Association), USAAS/NZS 1477:2017 · Standards Australia / Standards New Zealand, Australia & New ZealandASTM D3139-18 · ASTM International, USA
Typically used with
IS 4985IS 6307IS 12235
Also on InfraLens for IS 10124
6Key values4Tables4FAQs

BIM-relevant code. See the BIM Hub for ISO 19650, IFC, and LOD/LOIN frameworks used alongside it.

Practical Notes
! These pipes are specifically designated as 'Agri' pipes and should not be confused with or substituted for potable water pipes under IS 4985.
! The standard covers both plain-ended suction pipes and delivery pipes which may have an integral socket.
! Ensure proper storage away from direct sunlight to prevent UV degradation and brittleness.
Frequently referenced clauses
Cl. 4MaterialCl. 5DimensionsCl. 6Physical and Mechanical PropertiesCl. 8Performance Requirements (Opacity, Acid Resistance, Hydrostatic Pressure Test)Cl. 11Marking
Pulled from IS 10124:2000. Browse the full clause & table index below in Tables & Referenced Sections.
uPVCplasticPVC

International Equivalents

Similar International Standards
EN ISO 1452-3:2022CEN / ISO (European Committee for Standardization / International Organization for Standardization), Europe/International
HighCurrent
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 3: Fittings
Covers requirements for both moulded and fabricated PVC-U fittings for pressure water systems.
AWWA C907-20AWWA (American Water Works Association), USA
HighCurrent
Polyvinyl Chloride (PVC) Pressure Fittings for Water, 4 In. Through 12 In. (100 mm Through 300 mm)
Specifically covers fabricated PVC pressure fittings, aligning very closely with the IS scope.
AS/NZS 1477:2017Standards Australia / Standards New Zealand, Australia & New Zealand
MediumCurrent
PVC-U pipes and fittings for pressure applications
A combined standard for pipes and fittings, which includes specific requirements for fabricated fittings.
ASTM D3139-18ASTM International, USA
LowCurrent
Standard Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals
Focuses on elastomeric seal joints, which may be a component of fabricated fittings, but does not cover the fitting itself.
Key Differences
≠IS 10124:2000 uses a reference temperature of 27°C for pressure ratings and testing, reflecting Indian climatic conditions, whereas EN ISO and other international standards typically use 20°C.
≠The Indian standard specifies a limited range of pressure classes (2.5, 4, 6, 10, 12.5 kgf/cm²), which are distinct from the PN (Nominal Pressure) ratings in the ISO/EN system or the Class/Schedule system in US standards.
≠IS 10124:2000 is older and may lack some advanced testing requirements found in newer standards like AWWA C907-20, such as long-term resistance to disinfectants like chlorine and chloramine.
≠Marking requirements are different; IS 10124 mandates the ISI Certification Mark, which is not a requirement in international standards that have their own specific marking protocols (e.g., NSF-pw mark for AWWA).
Key Similarities
≈All standards mandate that fabricated fittings be made from pipe that conforms to a recognized standard for PVC-U pressure pipes (e.g., IS 4985 for IS 10124).
≈The fundamental material requirement across all standards is the use of unplasticized polyvinyl chloride (PVC-U) compound suitable for contact with potable water.
≈Core performance tests such as the short-term hydrostatic pressure test, opacity test (to prevent algae growth), and heat reversion test are common requirements to ensure structural integrity and stability.
≈All standards specify dimensional controls for solvent cement sockets and spigots to ensure proper interference fits and reliable jointing.
Parameter Comparison
ParameterIS ValueInternationalSource
Vicat Softening Temperature (VST) of MaterialMinimum 79°C (as per material spec IS 10148)≥ 80°CEN ISO 1452-3
Heat Reversion TestMax 5% change at 150°CMax 5% change at 150°C (when tested per ISO 2507-1)EN ISO 1452-3
Short-Term Hydrostatic Test Stress42.0 MPa induced stress at 27°C for 1 hour40.0 MPa induced stress at 20°C for 1 hourEN ISO 1452-3
OpacityLight transmission shall not be more than 0.2%Light transmission shall be less than 0.2%AS/NZS 1477
Standard ColourDark greyGrey, blue, or cream (typically grey for fittings)AS/NZS 1477
Reference Temperature for Ratings27°C20°CEN ISO 1452-3
⚠ Verify details from original standards before use

Key Values6

Quick Reference Values
Minimum Vicat Softening Temperature76 °C
Maximum Longitudinal Reversion5 %
Density Range1.40 to 1.46 g/cm³
Maximum Light Transmission (Opacity Test)0.2 %
Standard Pipe Lengths3 m and 6 m
Pressure Classes4, 6, 8, and 10 kgf/cm²
Key Formulas
σ = P(D-t) / 2t — Hoop stress calculation for hydrostatic pressure testing

Tables & Referenced Sections

Key Tables
Table 1 - Dimensions of Rigid uPVC Pipes for Suction and Delivery Lines
Table 2 - Physical Properties of Pipes
Table 3 - Requirement for Sulphuric Acid Test
Table 4 - Hydrostatic Stress for Pipes for Acceptance Test
Key Clauses
Clause 4 - Material
Clause 5 - Dimensions
Clause 6 - Physical and Mechanical Properties
Clause 8 - Performance Requirements (Opacity, Acid Resistance, Hydrostatic Pressure Test)
Clause 11 - Marking

Related Resources on InfraLens

Cross-Referenced Codes
IS 4985:2021Unplasticized PVC (uPVC) pipes for potable wa...
→
IS 6307:2018Porcelain Insulators for Overhead Power Lines
→
IS 12235:2000Thermoplastics Pipes and Fittings - Methods o...
→

Frequently Asked Questions4

What are the standard pressure ratings for these agricultural pipes?+
The standard specifies pressure classes of 4, 6, 8, and 10 kgf/cm² (Clause 5.3).
What is the maximum reversion allowed for these pipes?+
The longitudinal reversion must not exceed 5% when tested according to IS 12235 (Part 5) (Table 2).
Can IS 10124 pipes be used for drinking water supply?+
No, this standard is for agricultural pump sets. Pipes for potable water supply are covered by IS 4985.
What is the minimum Vicat softening temperature?+
The minimum Vicat softening temperature should be 76°C when tested as per IS 6307 (Table 2).

QA/QC Inspection Templates

📋
QA/QC templates coming soon for this code.
Browse all 300 templates →