| S.No. | Field / Checkpoint | Reference | Status |
|---|---|---|---|
| A. BEAM POUR DETAILS | |||
| A1 | Beam ID + floor + grid + length + cross section Acceptance: Unique | Per GFC | OK NC NA |
| A2 | Grade + volume + pour start / end time Acceptance: No cold joint | Continuous pour | OK NC NA |
| B. PRE-POUR CHECKS | |||
| B1 | Rebar + formwork inspections signed Acceptance: Both signed by QC + consultant | Hold-point clearance | OK NC NA |
| B2 | Cover blocks placed + camber if specified Acceptance: Per drawing | Bottom cover 25mm typical | OK NC NA |
| B3 | Construction joint preparation (if any) Acceptance: Per IS 456 Cl. 13.4 | Roughened + wetted + neat cement | OK NC NA |
| C. PLACING + COMPACTION | |||
| C1 | Concrete placed in layers ≤ 50cm Acceptance: Layered placement | IS 456 Cl. 13.3 | OK NC NA |
| C2 | Internal vibration — needle vibrator Acceptance: Honeycombing avoided | Insertion every 50cm × duration 10-15 sec | OK NC NA |
| C3 | Cubes cast + slump tested every load Acceptance: 1 set per 1-50 m³ | Per IS 456 Cl. 15 | OK NC NA |