IS 7742 Part 2

: 1991

Flushing cisterns for water closets and urinals, Part 2: Vitreous china flushing cisterns (First Revision)

CurrentFrequently UsedSpecificationBIMMEP · Environmental and Sanitation
Archive.orgBIS PortalGoogle

This standard specifies the requirements for materials, dimensions, construction, and flushing performance of vitreous china flushing cisterns. It covers various capacities for use with water closets and urinals, and details the test methods to verify quality, durability, and functional efficiency.

Specifies requirements for vitreous china flushing cisterns used with water closets and urinals.

Quick Reference Values
Maximum Water Absorption0.5 percent by mass
Minimum Average Flushing Rate (10 Litre Cistern)2.2 litres/second
Crazing Test Temperature130 ± 5 °C
Maximum Noise Level for Ball Valve Operation30 dB(A)
Standard Flushing Capacities5, 6.3, 7.5, 9, 10, 11, 12.5 and 15 litres
Practical Notes
Vitreous china offers superior stain resistance and hygiene compared to plastic cisterns, but is significantly heavier and more susceptible to impact damage.
Ensure the internal fittings (float valve and syphon mechanism) also conform to their respective IS codes (IS 1703, IS 8931) as they are critical for the cistern's performance and water efficiency.
This standard predates modern dual-flush systems; while it covers various single-flush capacities, newer water-saving fixtures may be governed by more recent standards or manufacturer specifications.