Bathroom Ventilation — Min Window Area

Minimum openable window area for bath/WC
See also📖 NBC 2016🔗 IS 2065🧮 RCC Design📒 Handbook
0.37
0.37 m²BATH VENT — WINDOW
Primary value0.37 m²
Applies toBathrooms with external wall · WCs with external wall
ExceptionsInternal bathrooms (no ext wall)Mechanical exhaust required
Measured asOpenable window area connecting to outside air (not internal courtyard <3m wide).
SourceNBC 2016Part 4, Clause 4.3
✓ Verified
Why this matters

Bathrooms generate steam, odours, and humidity that damage finishes and breed mould. 0.37 m² is the smallest opening that lets natural ventilation clear these in normal use.

Typical practice

Most bathrooms provide 0.5-0.7 m² of high-level window (above eye level for privacy) plus a powered exhaust fan for fast removal.