BOQ Builder·Auto-BOQ from dimensions, DSR ratesNEWBidEasy·Government tenders, searchableLIVEInfraLens App·Free on Play Store, offline-readyNEW
Home · DCR · Nellore Setbacks

Nellore Setback Rules

Nellore Municipal Corporation (NMC) · Directorate of Town & Country Planning, AP (DTCP)

Regulation: G.O. Ms. 168 (AP)Category: G.O. Ms. 168 (AP) — Nellore (NMC + DTCP)Reviewed: 2026-06-02Draft
Download G.O. Ms. 168 (AP) PDF
Revised Common Building Rules — G.O. Ms. No. 168, M.A. & U.D. Department
Govt. of Telangana, Municipal Administration & Urban Development Department · effective 2012-04-07 · hosted on G.O. Ms. 168 (AP) — official Andhra Pradesh regulation

The G.O. Ms. 168 (AP) is the operative bye-law governing setbacks, building height, and FSI for plots in Nellore under NMC / DTCP jurisdiction (Category G.O. Ms. 168 (AP) — Nellore (NMC + DTCP)). Front-side margin is driven by abutting road width; side and rear margins for single-family dwellings depend on plot size; for apartments and other uses the side and rear margins scale with building height. Use the calculator below for a quick lookup, or scroll to the full tables.

Quick Setback Lookup
Front (Road-side)
1.5 m
From Table III, G.O. Ms. 168 (front by plot size + road width)
Side
1 m
Table II, G.O. Ms. 168 (all-round setback for buildings ≤ 15 m)
Rear
1 m
Table II, G.O. Ms. 168 (all-round setback for buildings ≤ 15 m)
Max Height
15 m
From G.O. Ms. 168 (height vs road width / plot)
Setbacks here scale with building height — enter your proposed height. Values are minimums; verify against the full tables and the official source below.

Front Setback (Road-side Margin)

Source: Table III, G.O. Ms. 168 (front by plot size + road width) · Residential plots, buildings up to 15 m. Values shown are the floor for roads ≤ 12 m; front rises with road width.
Plot sizeFront setback
< 200 sq.m1.5 m
200 – 300 sq.m2 m
≥ 300 sq.m3 m

Side & Rear Setback — Single-Family Dwelling

Source: Table II, G.O. Ms. 168 (all-round setback for buildings ≤ 15 m) · Residential buildings up to 15 m height (G+3/G+4)
Plot sizeRear marginSide marginNotes
< 100 sq.mNot requiredNot requiredFront-only for small plots; rear ~1 m where required.
100 – 200 sq.m1 m1 mOne side 1.0 m, rear 1.0 m.
200 – 300 sq.m1.5 m1.5 mSide 1.5 m, rear 1.5 m.
300 – 500 sq.m2 m1.5 mSides 1.5 m, rear 2.0 m.
500 – 750 sq.m3 m2 mSides 2.0 m, rear 3.0 m.
750 – 1000 sq.m3.5 m2.5 mSides 2.5 m, rear 3.5 m.
1000 – 2000 sq.m4 m3 mSides 3.0 m, rear 4.0 m.
> 2000 sq.m5 m4 mSides 4.0 m, rear 5.0 m.

Side & Rear Setback — Apartments & Other Buildings

Source: Table IV, G.O. Ms. 168 (all-round setback by height) · Buildings taller than 15 m — uniform setback on ALL sides (incl. front)
Building heightRear marginSide marginNotes
> 15 & ≤ 21 m7 m7 mMinimum 7 m clear all sides (HMDA high-rise rule).
> 21 & ≤ 24 m8 m8 m
> 24 & ≤ 27 m9 m9 m
> 27 & ≤ 30 m10 m10 m
> 30 & ≤ 35 m11 m11 m
> 35 & ≤ 40 m12 m12 m
> 40 & ≤ 45 m13 m13 m
> 45 & ≤ 50 m14 m14 m
> 50 & ≤ 55 m16 m16 m
> 55 m16 m + 0.5 per 5 m16 m + 0.5 per 5 m16 m at 55 m, plus 0.5 m for every additional 5 m of height. AAI clearance + DCFE NOC.

Maximum Building Height

Source: G.O. Ms. 168 (height vs road width / plot) · GHMC + HMDA — also bounded by FAR and plot size
Road widthMax heightNotes
< 9 m12 mIndividual residential up to ~12 m after road-widening to 4.5 m centre-line.
9 – < 12 m15 mUp to ~15 m (G+4/G+5) — high-rise threshold.
12 – < 18 m18 m
18 – < 24 m30 mUp to ~30 m on an 18 m road (high-rise).
24 – < 30 m45 m
≥ 30 mNo limitNo fixed cap — FAR + AAI + DCFE NOC govern.

Worked Examples

100 sq.m residential plot, ~10 m height
Use:Single-family (low-rise)
Front setback:1.5 m
Side setback:Not required
Rear setback:Not required
Max height:12 m
< 100 / small plot: front 1.5 m, minimal side/rear. Road < 9 m → ~12 m height.
300 sq.m plot, ~12 m height, 12 m road
Use:Single-family (low-rise)
Front setback:2 m
Side setback:1.5 m
Rear setback:1.5 m
Max height:15 m
200–300 band: front 2 m (≤12 m road), side 1.5 m, rear 1.5 m.
High-rise apartment, 25 m height, 2000 sq.m plot, 18 m road
Use:High-rise (> 15 m)
Front setback:9 m
Side setback:9 m
Rear setback:9 m
Max height:30 m
> 15 m → Table IV uniform all-round setback; 25 m → 9 m on every side. DCFE NOC required.
Tall tower, 50 m height, 5000 sq.m plot, 24 m road
Use:High-rise tower
Front setback:14 m
Side setback:14 m
Rear setback:14 m
Max height:45 m
50 m → 14 m all-round (Table IV). Above 55 m adds 0.5 m per 5 m.

Key Definitions

TS-bPASS
Telangana State Building Permission Approval & Self-certification System — the online permission portal for GHMC + HMDA.
High-rise Building
Height > 15 m. Switches from the plot-size side/rear table to a uniform all-round setback by height (Table IV, min 7 m). Needs ≥12 m road, structural review and DCFE NOC.
G.O. Ms. 168
Revised Common Building Rules (2012), the primary building regulation for GHMC + HMDA.
All-round setback
For high-rise, the front, side and rear setbacks are all equal (uniform), unlike low-rise where they differ.

Nellore Setback & Bye-law Reference Guide

What governs setbacks in Nellore?

Building setbacks in Nellore are regulated by the Revised Common Building Rules — G.O. Ms. No. 168, M.A. & U.D. Department (G.O. Ms. 168 (AP)), notified by the Govt. of Telangana, Municipal Administration & Urban Development Department on 2012-04-07. The regulation applies across all Category G.O. Ms. 168 (AP) — Nellore (NMC + DTCP) areas — meaning both the Nellore Municipal Corporation (NMC) city limits and the broader Directorate of Town & Country Planning, AP (DTCP) jurisdiction. Three structural factors determine your minimum setbacks: abutting road width (controls front margin and max height), plot size (controls side/rear for single-family), and building height (controls side/rear for apartments).

Front setback — driven by road width

The front (road-side) margin under G.O. Ms. 168 (AP) starts at 2.5 m for roads up to 9 m wide and scales up to 9.0 m for roads 45 m and wider. For most residential plots in Nellore on a typical 30-40 ft (9-12 m) road, the front setback is 2.5 to 3.0 m. Corner plots must observe the road-side margin on every abutting road, which can significantly reduce buildable area on tight plots. Special buildings — high-rises above 25 m, hospitals, hotels, malls, educational institutions — must keep a uniform 12.0 m road-side margin regardless of road width.

Side and rear margins — driven by plot size for residences

For single-family and two-family dwellings (DW1 and DW2 in G.O. Ms. 168 (AP) terminology), side and rear margins are determined by plot area. Tiny plots up to 25 sq.m are exempt (with G+1 cap). Plots between 25 and 150 sq.m need only 1.0-1.5 m on any one side. Once plot size crosses 150 sq.m, a mandatory 2.0 m rear margin kicks in. Plots above 500 sq.m must keep 3.0 m on both sides plus 3.0 m rear. This graduated structure gives smaller, dense urban plots more buildable area while ensuring breathing room in larger plots.

Apartments and commercial — driven by building height

Multi-family, mixed-use, and commercial buildings (anything other than DW1-DW2 and industrial) follow a different logic: the taller the building, the larger the side and rear margins. A low-rise apartment up to 16.5 m needs 3.0 m on every side. Buildings between 16.5 and 25 m need 4.0 m. Buildings between 25 and 45 m need 6.0 m. Anything above 45 m needs 8.0 m. This scaling protects fire access and inter-building daylight as buildings get taller.

Margin between buildings on the same plot

Group housing schemes and multi-block developments must observe an internal margin between buildings as well, separate from plot boundaries. Per Table 6.25, this ranges from 4.5 m for buildings up to 16.5 m, to 12.0 m between buildings of 70 m. Margin from a designated common plot (open recreation area within a layout) is 3.0 m for buildings up to 25 m, and 6.0 m above that. These rules are critical at the master-plan stage; missing them means redesigning blocks late in DA approval.

Coverage of overlays and special zones

The setback tables on this page cover the standard Category G.O. Ms. 168 (AP) — Nellore (NMC + DTCP) rules. Nellore additionally has overlay zones with their own special regulations: the Sabarmati Riverfront Development zone, GAMTAL (urbanised village) areas, Core Walled City (heritage), Smart City Node (SPD5), Knowledge Precinct, and Closed Textile Mills Zone (CZ). Plots within these overlays follow the standard setback rules plus the overlay-specific provisions in Sections 7.2-7.6 and 8.1-8.4 of G.O. Ms. 168 (AP). If your plot is in any of these zones, consult the full G.O. Ms. 168 (AP) PDF (download link at the top of this page) before designing.

Frequently asked questions

What is the minimum front setback for a residential plot in Nellore?

Per G.O. Ms. 168 (AP) Table 6.24, the minimum road-side margin (front setback) for Category D1 plots in Nellore ranges from 2.5 m on roads up to 9 m wide, to 9.0 m on roads of 45 m or more. For a typical 30 ft (≈9 m) wide road, the front setback is 2.5 m; for a 40 ft (≈12 m) road it's 3.0 m; for an 18 m road it jumps to 6.0 m.

What is the side and rear setback for a 200 sq.m plot in Nellore?

For a single-family dwelling on a plot between 150 and 300 sq.m, G.O. Ms. 168 (AP) requires a rear margin of 2.0 m and a side margin of 1.5 m on any one side. The other side may abut the boundary. This is per Table 6.26 of the regulation.

What is the maximum building height allowed in Nellore?

Maximum building height under G.O. Ms. 168 (AP) is governed by the abutting road width (Table 6.23). On roads less than 9 m wide, height is capped at 10 m (12 m for DW1/DW2 type residential). On 9-12 m roads it goes up to 16.5 m, on 12-18 m roads up to 30 m, and on 18 m and wider roads up to 45 m. In High Density Development Areas (where permitted FSI exceeds 3.5) on 18 m+ roads, height up to 70 m is allowed within 200 m of the road.

Are setback rules different for apartments vs single-family homes in Nellore?

Yes. Single-family dwellings (Dwelling 1 and Dwelling 2 in G.O. Ms. 168 (AP)) have setbacks driven by plot size (Table 6.26). Apartments and other multi-family or commercial buildings have setbacks driven by building height — 3.0 m for buildings up to 16.5 m, 4.0 m for 16.5-25 m, 6.0 m for 25-45 m, and 8.0 m for buildings above 45 m. Front (road-side) margins follow the same Table 6.24 for both categories.

How do I calculate setbacks for my plot in Nellore?

Use three inputs: (1) plot size in square metres, (2) abutting road width in metres, and (3) intended use (single-family, apartment, commercial). The lookup tables on this page give exact values per G.O. Ms. 168 (AP). For corner plots, road-side margin applies on every abutting side. The setback calculator at the top of this page returns front, side, rear, and max height in one click.

Where can I download the official G.O. Ms. 168 (AP) document?

The official Revised Common Building Rules — G.O. Ms. No. 168, M.A. & U.D. Department PDF is published by the Govt. of Telangana, Municipal Administration & Urban Development Department and hosted on G.O. Ms. 168 (AP) — official Andhra Pradesh regulation. Use the "Download PDF" button at the top of this page for direct access. The regulation is approximately 600 pages; setbacks are covered in Section 6.7 (Margins) and Tables 6.23 through 6.41.

Do these rules apply to plots in AUDA areas outside the AMC limit?

Yes — G.O. Ms. 168 (AP) is a state-level regulation that applies uniformly across Category D1 plots, which covers both AMC (city corporation) and AUDA (urban development authority) jurisdictions. The same Tables 6.24 and 6.26 govern setbacks. Gandhinagar Municipal Corporation (GMC) plots fall under separate tables (6.28 onwards) due to its planned-grid layout. Special zones (Riverfront, Heritage Core, GAMTAL, Smart City Node) have their own overlay rules in addition to base setbacks.

What happens if my plot doesn't meet the minimum setback?

Existing buildings in revenue records before the publication of G.O. Ms. 168 (AP) are typically protected by transitional provisions. New construction or major alteration must comply with current setbacks. For sub-25 sq.m plots, only G+1 construction is permitted with no mandatory setback. For plots affected by road widening, owners can claim FSI compensation against the original boundary (Section 6.3.3) provided the surrendered land is formally transferred. Always consult a licensed architect for plot-specific guidance.

Source citation: Revised Common Building Rules — G.O. Ms. No. 168, M.A. & U.D. Department (G.O. Ms. 168 (AP)), Govt. of Telangana, Municipal Administration & Urban Development Department, effective 2012-04-07. View official PDF on G.O. Ms. 168 (AP) — official Andhra Pradesh regulation

Nellore follows the Revised Common Building Rules — G.O. Ms. No. 168, M.A. & U.D. Department, the state-wide Andhra Pradesh code, administered by Nellore Municipal Corporation, Directorate of Town & Country Planning, AP. Setback, FSI and height tables are the state standard.
Reference only — not a substitute for NMC / DTCP approval. G.O. Ms. 168 (AP) has been amended multiple times since publication; corrigenda are issued periodically. Setbacks for special buildings, non-T.P. areas, and zone-specific overlays (Heritage Core, GAMTAL, Riverfront, Smart City Node, etc.) are governed by separate sections not fully covered above. Verify with a licensed architect or directly with the NMC Town Development Department before applying for development permission. InfraLens accepts no liability for construction decisions made using this reference.