Hyderabad Setback Rules
Greater Hyderabad Municipal Corporation (GHMC) · Hyderabad Metropolitan Development Authority (HMDA)
The G.O. Ms. 168 (TS-bPASS) is the operative bye-law governing setbacks, building height, and FSI for plots in Hyderabad under GHMC / HMDA jurisdiction (Category G.O. Ms. No. 168 (Revised Common Building Rules) — implemented via TS-bPASS). Front-side margin is driven by abutting road width; side and rear margins for single-family dwellings depend on plot size; for apartments and other uses the side and rear margins scale with building height. Use the calculator below for a quick lookup, or scroll to the full tables.
Front Setback (Road-side Margin)
| Road width | Front setback |
|---|---|
| 0 m | |
| 1 m | |
| 1.5 m | |
| 2 m | |
| 3 m | |
| 4 m | |
| 5 m | |
| 6 m | |
| 7 m |
- Subject to abutting road width — for plots on roads ≥30 m, minimum front setback is 6 m irrespective of plot size.
- For corner plots, front setback applies on every abutting road (or splay area, whichever is wider).
Side & Rear Setback — Apartments & Other Buildings
| Building height | Rear margin | Side margin | Notes |
|---|---|---|---|
| > 15 & ≤ 18 m | 5 m | 5 m | — |
| > 18 & ≤ 24 m | 6 m | 6 m | — |
| > 24 & ≤ 27 m | 7 m | 7 m | Minimum 7 m clear all sides for high-rise per HMDA amendment |
| > 27 & ≤ 30 m | 8 m | 8 m | — |
| > 30 & ≤ 36 m | 9 m | 9 m | — |
| > 36 & ≤ 45 m | 10 m | 10 m | — |
| > 45 m | 12 m | 12 m | Minimum 12 m all sides; +1 m per additional 3 m height. Subject to AAI clearance + DCFE NOC. |
- Even with concessions, minimum clear setback of 7.0 m must be maintained on all sides for buildings >15 m, per HMDA amendments.
- High-rise buildings require minimum 12 m wide abutting road, structural design review, and Director Fire Services NOC.
Maximum Building Height
| Road width | Max height | Notes |
|---|---|---|
| < 9 m | 10 m | G+2 / G+3 typical |
| 9 - 12 m | 15 m | G+4 / G+5 — boundary of high-rise threshold |
| 12 - 18 m | 18 m | G+5 |
| 18 - 24 m | 24 m | G+7 |
| 24 - 30 m | 30 m | G+9 |
| ≥ 30 m | 999 m | No upper cap — subject to AAI clearance, FAR per zone (typical 1.5-3.5) |
- Hyderabad (Rajiv Gandhi International Airport) approach corridor + Begumpet airport — AAI clearance required for plots within prescribed zones.
- Permissions issued via TS-bPASS online portal.
Worked Examples
Key Definitions
Hyderabad Setback & Bye-law Reference Guide
What governs setbacks in Hyderabad?
Building setbacks in Hyderabad are regulated by the Revised Common Building Rules — G.O. Ms. No. 168, M.A. & UD Department (G.O. Ms. 168 (TS-bPASS)), notified by the Govt. of Telangana, Municipal Administration & Urban Development Department on 2012-04-07. The regulation applies across all Category G.O. Ms. No. 168 (Revised Common Building Rules) — implemented via TS-bPASS areas — meaning both the Greater Hyderabad Municipal Corporation (GHMC) city limits and the broader Hyderabad Metropolitan Development Authority (HMDA) jurisdiction. Three structural factors determine your minimum setbacks: abutting road width (controls front margin and max height), plot size (controls side/rear for single-family), and building height (controls side/rear for apartments).
Front setback — driven by road width
The front (road-side) margin under G.O. Ms. 168 (TS-bPASS) starts at 2.5 m for roads up to 9 m wide and scales up to 9.0 m for roads 45 m and wider. For most residential plots in Hyderabad on a typical 30-40 ft (9-12 m) road, the front setback is 2.5 to 3.0 m. Corner plots must observe the road-side margin on every abutting road, which can significantly reduce buildable area on tight plots. Special buildings — high-rises above 25 m, hospitals, hotels, malls, educational institutions — must keep a uniform 12.0 m road-side margin regardless of road width.
Side and rear margins — driven by plot size for residences
For single-family and two-family dwellings (DW1 and DW2 in G.O. Ms. 168 (TS-bPASS) terminology), side and rear margins are determined by plot area. Tiny plots up to 25 sq.m are exempt (with G+1 cap). Plots between 25 and 150 sq.m need only 1.0-1.5 m on any one side. Once plot size crosses 150 sq.m, a mandatory 2.0 m rear margin kicks in. Plots above 500 sq.m must keep 3.0 m on both sides plus 3.0 m rear. This graduated structure gives smaller, dense urban plots more buildable area while ensuring breathing room in larger plots.
Apartments and commercial — driven by building height
Multi-family, mixed-use, and commercial buildings (anything other than DW1-DW2 and industrial) follow a different logic: the taller the building, the larger the side and rear margins. A low-rise apartment up to 16.5 m needs 3.0 m on every side. Buildings between 16.5 and 25 m need 4.0 m. Buildings between 25 and 45 m need 6.0 m. Anything above 45 m needs 8.0 m. This scaling protects fire access and inter-building daylight as buildings get taller.
Margin between buildings on the same plot
Group housing schemes and multi-block developments must observe an internal margin between buildings as well, separate from plot boundaries. Per Table 6.25, this ranges from 4.5 m for buildings up to 16.5 m, to 12.0 m between buildings of 70 m. Margin from a designated common plot (open recreation area within a layout) is 3.0 m for buildings up to 25 m, and 6.0 m above that. These rules are critical at the master-plan stage; missing them means redesigning blocks late in DA approval.
Coverage of overlays and special zones
The setback tables on this page cover the standard Category G.O. Ms. No. 168 (Revised Common Building Rules) — implemented via TS-bPASS rules. Hyderabad additionally has overlay zones with their own special regulations: the Sabarmati Riverfront Development zone, GAMTAL (urbanised village) areas, Core Walled City (heritage), Smart City Node (SPD5), Knowledge Precinct, and Closed Textile Mills Zone (CZ). Plots within these overlays follow the standard setback rules plus the overlay-specific provisions in Sections 7.2-7.6 and 8.1-8.4 of G.O. Ms. 168 (TS-bPASS). If your plot is in any of these zones, consult the full G.O. Ms. 168 (TS-bPASS) PDF (download link at the top of this page) before designing.
Frequently asked questions
What is the minimum front setback for a residential plot in Hyderabad?
Per G.O. Ms. 168 (TS-bPASS) Table 6.24, the minimum road-side margin (front setback) for Category D1 plots in Hyderabad ranges from 2.5 m on roads up to 9 m wide, to 9.0 m on roads of 45 m or more. For a typical 30 ft (≈9 m) wide road, the front setback is 2.5 m; for a 40 ft (≈12 m) road it's 3.0 m; for an 18 m road it jumps to 6.0 m.
What is the side and rear setback for a 200 sq.m plot in Hyderabad?
For a single-family dwelling on a plot between 150 and 300 sq.m, G.O. Ms. 168 (TS-bPASS) requires a rear margin of 2.0 m and a side margin of 1.5 m on any one side. The other side may abut the boundary. This is per Table 6.26 of the regulation.
What is the maximum building height allowed in Hyderabad?
Maximum building height under G.O. Ms. 168 (TS-bPASS) is governed by the abutting road width (Table 6.23). On roads less than 9 m wide, height is capped at 10 m (12 m for DW1/DW2 type residential). On 9-12 m roads it goes up to 16.5 m, on 12-18 m roads up to 30 m, and on 18 m and wider roads up to 45 m. In High Density Development Areas (where permitted FSI exceeds 3.5) on 18 m+ roads, height up to 70 m is allowed within 200 m of the road.
Are setback rules different for apartments vs single-family homes in Hyderabad?
Yes. Single-family dwellings (Dwelling 1 and Dwelling 2 in G.O. Ms. 168 (TS-bPASS)) have setbacks driven by plot size (Table 6.26). Apartments and other multi-family or commercial buildings have setbacks driven by building height — 3.0 m for buildings up to 16.5 m, 4.0 m for 16.5-25 m, 6.0 m for 25-45 m, and 8.0 m for buildings above 45 m. Front (road-side) margins follow the same Table 6.24 for both categories.
How do I calculate setbacks for my plot in Hyderabad?
Use three inputs: (1) plot size in square metres, (2) abutting road width in metres, and (3) intended use (single-family, apartment, commercial). The lookup tables on this page give exact values per G.O. Ms. 168 (TS-bPASS). For corner plots, road-side margin applies on every abutting side. The setback calculator at the top of this page returns front, side, rear, and max height in one click.
Where can I download the official G.O. Ms. 168 (TS-bPASS) document?
The official Revised Common Building Rules — G.O. Ms. No. 168, M.A. & UD Department PDF is published by the Govt. of Telangana, Municipal Administration & Urban Development Department and hosted on hmda.gov.in (HMDA Revised Building Rules official). Use the "Download PDF" button at the top of this page for direct access. The regulation is approximately 600 pages; setbacks are covered in Section 6.7 (Margins) and Tables 6.23 through 6.41.
Do these rules apply to plots in AUDA areas outside the AMC limit?
Yes — G.O. Ms. 168 (TS-bPASS) is a state-level regulation that applies uniformly across Category D1 plots, which covers both AMC (city corporation) and AUDA (urban development authority) jurisdictions. The same Tables 6.24 and 6.26 govern setbacks. Gandhinagar Municipal Corporation (GMC) plots fall under separate tables (6.28 onwards) due to its planned-grid layout. Special zones (Riverfront, Heritage Core, GAMTAL, Smart City Node) have their own overlay rules in addition to base setbacks.
What happens if my plot doesn't meet the minimum setback?
Existing buildings in revenue records before the publication of G.O. Ms. 168 (TS-bPASS) are typically protected by transitional provisions. New construction or major alteration must comply with current setbacks. For sub-25 sq.m plots, only G+1 construction is permitted with no mandatory setback. For plots affected by road widening, owners can claim FSI compensation against the original boundary (Section 6.3.3) provided the surrendered land is formally transferred. Always consult a licensed architect for plot-specific guidance.
Hyderabad and HMDA jurisdiction follow G.O. Ms. No. 168 (originally issued by AP, retained by Telangana with amendments). Permissions are processed online via TS-bPASS. Setback rules are graded by plot area + abutting road width; high-rise buildings (>15 m or G+5) require all-sides minimum 7 m setback.